Watson Dermatome (Skin Graft Knife)

Watson Dermatome (Skin Graft Knife) was developed by Watson Johnson in 1960. This manual dermatome has a polished, stainless-steel guard and a simpler, more rigid thickness adjustment compared to Humby – Braithwaite Dermatome.

  • Depth Of Cut Adjustable By Rod Rotation
  • Precision Fit “No Play” in use
  • Adjustable Cut Thickness From 0.1mm To 1.2mm
  • Max Cut Width 155mm, 30.5 cm (12″) Inches


SKU:06f4eb58cbe8

The rod of Watson Dermatome (Skin Graft Knife) has no independent movement, either sliding or rotation, while the graft is being taken. At its end-bearings, it passes eccentrically through the bushes; hence, the depth of cut can be set by rotation of the rod with a single knurled control knob, the rod remaining parallel to the blade at all settings. With this arrangement, the bearings can have a precision fit and there is no “play” in use. While cutting the graft, spontaneous rotation of the rod is slight, but a locking lever is provided to avoid accidental alteration of the setting once it has been made.

HISTORICAL INSIGHT

While this fixed guard effectively dealt with the problem of skin rolling around the guard, it introduced a considerable degree of “drag” due to the inability of the guard to slide to and fro with the skin surface. This drag is only partially eliminated by lubrication with liquid paraffin, and the edges of both graft and donor site tend to be rather ragged when a Watson Dermatome (Skin Graft Knife) has been used.

Cobbett proposed a modification to this problem of avoiding drag and still preventing the skin rolling around the guard that would be to have a guard that could slide to and fro but could not rotate. Such a modification to a standard Braithwaite knife was made by cutting a “D” section instead of a circular hole in the guard end of one of the cam levers and grinding a corresponding flat on the side of the end of the guard. This modified knife has little drag and no tendency for the skin to roll up on the guard

REFERENCES: Ameer F, Singh AK, Kumar S. Evolution of instruments for harvest of the skin grafts. Indian J Plast Surg 2013;46:28-35.

Author Name

Watson

Specialty

Orthopedic, Plastic Surgery, Skin Grafting

Sub-Category

Skin Graft Knives

Category

Knives, Needles & Picks

Handle Type

Hollow Handle

Overall Length

30.5 cm – 12″

Finish

Satin

Material

Stainless Steel

CE Marking

Yes

Reusable

Yes

Used in Specialties: Orthopedic
Plastic Surgery
Skin Grafting
Product Category: Knives, Needles & Picks
Product Type: Skin Graft Knives

Bestsellers

Double Ended Bone Curette

(0 Reviews)
Double Ended Bone Curette is a specialized orthopedic tool that surgeons commonly use for removing fibrous and bony tissue, as well as debris and diseased material, from bone and joint surfaces.
  • Round & Oval Tips for Scraping Tissue With Ease.
  • Solid Straight Shanks for Deep Surgical Access.
  • Ergonomic Solid Handle for Superior Control.

Fergusson Suction Tube

(0 Reviews)
Fergusson Suction Tube is a specialized device that surgeons in multiple areas use to traverse narrow spaces, absorb fluids and debris, and provide a clear working space during surgery.
  • Strongly Curved Profile Ensuring Optimal Sightlines.
  • 19.5cm Overall Length to Reach Deep Cavities.
  • Cleaning Wire for Removing Trapped Objects.

Flush Cut Distal End Cutter

(0 Reviews)
The Flush Cut Distal End Cutter is an orthodontic tool used to cut the distal end of arch wires extending out of the molar tubes
  • ULTRA CUT Technology With Tungsten Carbide Fused Cutting Edge For Maximum Efficiency & Durability
  • Ultra Thin Beaks Leaving No Trace Of The Wire
  • Ergonomic Grip To Decrease Effort
New Dimension in Cutting Performance Tungsten Carbide Inserts Enabling 6x Performance

Gluck Rib Shear

(0 Reviews)
The ® Gluck Rib Shear is a specialized surgical instrument commonly used for cutting bones to gain access to the internal organs. It is frequently used during orthopedic as well as cardiovascular procedures.
  • Sharp Blades For Precise Dissection
  • Heavy Built To Decrease User Fatigue
  • Ergonomic Design For Comfortable Handling

Heiss Artery Forcep

(0 Reviews)
Heiss Artery Forcep is a specialized device that surgeons use to clamp blood vessels, especially small arteries, during a variety of surgical scenarios. The instrument is also useful to grasp disposable materials, tissues and needles.
  • Transverse Serrations to Prevent Endothelial Damage.
  • 1 x 2 Toothed Optional Patterns for Enhanced Clamping.
  • Ergonomic Finger Rings Ensuring Superior Control.

Inge Lamina Spreader

(0 Reviews)
The ® Inge Lamina Spreader is a specialized surgical instrument that is used for retracting small incision to give access for surgical manipulation. It is frequently used to spread the narrow incisions during orthopedic and spinal surgeries.
  • Toothed Tips For Secure Grip
  • Ergonomic Design For Comfortable Handling
  • Grip Handles For Superior Control

Kahre-Williger Periosteal Elevator

(0 Reviews)
Kahre-Williger Periosteal Elevator is an specialized orthopedic tool that surgeons frequently use for lifting and cutting the hard periosteum tissue and other adnexa from bone structures.
  • 4.0 & 5.0mm Blade Sizes for Dissecting Delicate Bones.
  • Versatile Curved Blade for Passing Into Narrow Spaces.
  • Ergonomic Solid Handle for Superior Surgical Control.
Product has been added to your cart